DAM MONITORING SYSTEM
SYSCOM MR3003DMS seismic monitoring system is the most compact, integrated and reliable system for dams, ensuring highest level of safety and sustainability. Automatic earthquake detection and structural monitoring will ensure the full integrity of the dam over its lifetime.
MR3003DMS is extremely versatile and easy to install, thanks to its state of the art Ethernet master-slave connectivity and the command & control access through embedded web server.
Three relays output (alarm 1, alarm 2 and device error) can be directly connected to the dam control room for a centralized overview and an automatic logic response in case of any seismic event that might occur.
MAJOR FEATURES
• IP66 compact unit containing tri-axial MEMS sensor, digital recorder, battery and communications
• No need of periodic calibration
• Internal terminals as junction box, AC/DC & Over Voltage Protection (OVP)
• Removable memory SD Card
• Up to 32 MR3003DMS in an Ethernet master-slave configuration network with common triggering and alarming
• Embedded Web Server for the configuration
• Fiber optics (FO) for long distances and highly reliable data stream
• Event recording principle with multiple level triggers
• Three configurable output relays for dam control monitoring system integration
• DDNS, OpenVPN, FTP push network capabilities
• Automatic sending of E-mail in case of event
• API REST interface available on request. Feel free to contact us for more information.
Technical Specification
Technical specifications | |
---|---|
Data acquisition - General - Principle - Resolution - Sampling-rate - Number of channels - Channel to channel skew - Dynamic range - Data filter - Trigger filter | 4th order delta-sigma ADC per channel 24 bits 50, 100, 200, 400, 500, 800, 1000, 2000sps 3 None, simultaneous sampling on all channels Typ. 130 dB @ 250 sps, 127 dB @ 500 sps Anti-aliasing filters Digital IIR filter: 0.5 – 15 Hz band-pass (Strong Motion Applications) |
Trigger and de-trigger - Principle - Trigger voting logic - Trigger level - STA / LTA - Smart trigger / De-trigger | Level trigger or STA/LTA or automatic adjustment of trigger level Predefined AND or OR combinations, individual channel votes 0.1 mg to 4 g STA: 0.1 to 25s, LTA: 1 to 250s, ratio 0.1:25 Automatic adjustment of trigger level |
Microprocessor Recording - Principle - Header - Pre-event recording - Post-event recording - Max. recording time - Memory removable Timing - System clock Data/User interface - Web interface - Intelligent Alert - FTP Built-in Alarm triggers - Principle - Alarm level range - User defined alarm - System status | Event recording (time history), continous time recording or manually triggered Contains status information at time of trigger and event summary 1-30s ( in 1 second steps) 1-100s ( in 1 second steps) Unlimited SD flash card (4GB) 1ppm, could be disciplined by GPS or NTP Easy to use command & control through embedded web server System initiates communications and sends e-mail when an event is recorded FTP client to push data to an FTP-server Two alarm levels independently settable as threshold levels or user-defined curves, with various notification options (individually setable for each axis) 0.1% to 100% full scale Thresholds and frequencies individual settable for each axis 3 Leds Run, Recording, Warning/Error. Internal LCD with status info and important settings |
Network capabilities - Common trigger & Common alarm - Sync. in LAN network - Max. number of MR3000DMS - Remote control | Configurable with AND/OR logic, for every device within the same network Typically 1 ms with NTP protocol 32, in Master/slave configuration VPN, DDNS |
Power Supply - Power supply - Internal battery - Consumption - Battery autonomy | 110-240 V AC, 50 – 60Hz, OVP Protected, type I and II. Optional DC power 10 – 36 VDC 12V, 12 Ah 4W (with charged battery), 25W (AC max. and battery in charge) Typ. 40 hours |
I/O (glands and connectors) - Relays (3) - Power - Kit LAN - Kit GPS - FO | M16 cable gland 7-11mm / Terminals M16 cable gland 4-11mm / Terminals On request, 3 m Ethernet cable On request, connector and GPS antenna with 5 m cable for time synchronization M20 cable gland 6-13 mm / ST connectors |
Fiber Optics - FO type | Multimode OM2 fiber with wavelength 1300nm, 50/125 μm, Rx/Tx |
Relays - Configuration - Current | 3 output configurable relays, No/Nc 2 A, 30 V DC |
Accelaration sensor - Principle - Hysteresis - Noise (10 to 1000 Hz) - Frequency range - Dynamic range - Measuring range - Sensitivity - Scale factor error - Orientation - Self test | Micro-machined capacity MEMS accelerometer None Typ. 7 μg/√ Hz DC to 600 Hz Typ. 100 dB @ 200 sps ±4 g 1.25 V/g differential < 1 % Horizontal or vertical mounting, to be specified when ordering Test-pulse, configurable |
Housing - Dimensions - Weight - Protection degree | 330 x 230 x 110 mm 10 Kg IP66 |
Environmental - Shock - Heat - Humidity | 30 g/11 ms half-sine -20 °C to +50°C up to 100% RH |
Regulations - EMC - Electrical safety - Conformity - Origin | IEC 61326-1 IEC 61010 CE Swiss Made |